Firebox (steam engine)

Steam engine firebox

The firedoor into the firebox of a steam locomotive. The firebox peak temperature is approximately 2,500 degrees F (~1371 ℃)
For other uses, see Firebox (disambiguation).

In a steam engine, the firebox is the area where the fuel is burned, producing heat to boil the water in the boiler. Most are somewhat box-shaped, hence the name. The hot gases generated in the firebox are pulled through a rack of tubes running through the firebox boiler.[1][2]

Steam locomotive fire tube firebox

Diagramatic section through an earlier steam locomotive boiler and firebox to the right. Note the boiler is not fitted with a superheater.

In the standard steam locomotive firetube type boiler, the firebox is surrounded by water space on five sides. The bottom of the firebox is open to atmospheric pressure, but covered by fire grates (solid fuel) or a firing pan (liquid fuel). If the engine burns solid fuel, like wood or coal, there is a grate covering most of the bottom of the firebox to hold the fire. An ashpan, mounted underneath the firebox and below the grates, catches and collects hot embers, ashes, and other solid combustion waste as it falls through the grates. In a coal-burning locomotive, the grates may be shaken to clean dead ash from the bottom of the fire. They are shaken either manually or (in larger locomotives) by a powered grate shaker. Wood-burning locomotives have fixed grates that can't be shaken. Wood ash is generally powder which will fall through the grates with no more agitation required than the vibrations of the locomotive rolling down the track. The fire grates must be replaced periodically due to the extreme heat they must endure. Combustion air enters through the bottom of the firebox and airflow is usually controlled by damper doors above the ash collection pocket of the ash pan. A locomotive that burns liquid fuel - usually "Bunker C" fuel oil or similar heavy oil - does not have grates. Instead, they have a heavy metal gauge firing pan bolted tight against the bottom of the firebox. The firing pan is covered with firebrick and the firebox has a firebrick lining, usually up to the level of the firebox door, all the way around the firebox. The oil burner is a nozzle containing a slot for the oil to flow out onto a steam jet which atomizes the oil into a fine mist which ignites in the firebox. The oil burner nozzle is usually mounted in the front of the firebox, protected by a hood of firebrick, and aimed at the firebrick wall below the firebox door. Dampers control air flow to the oil fire.

Brick arch

There is a large brick arch (made from fire brick) the front third to half of the firebox. It is supported on arch tubes, thermic syphons, or circulators. The brick arch directs heat, flames, and smoke back over the fire towards the rear of the firebox. Visible smoke contains unburned combustible carbon particles and combustible gasses. The purpose of this redirection is to cause more complete combustion of these particles and gasses which make the locomotive more efficient and causes less visible smoke to be emitted from the stack. Without the arch, flames and visible smoke would be sucked straight into the firetubes without having been fully burned, causing visible smoke to be emitted at the stack. The brick arch and its supports (arch tubes, thermic syphons, and circulators) require periodic replacement due to the extreme heat they endure.

Firetubes

Firetubes are attached to one wall of the firebox (the front wall for a longitudinal boiler, the top for a vertical boiler) and carry the hot gaseous products of combustion through the boiler water, heating it, before they escape to the atmosphere. Firetubes serve the additional purpose of staying the flat tube (flue) sheets (front and rear) so that only the top of the front flue sheet and the bottom of the rear flue sheet must be separately braced.

Sheets and stays

Cutaway of locomotive firebox and boiler with radial stays

The metal walls of the firebox are normally called sheets, which are separated and supported by stays. The stays support and brace the "sheets" (plates) against pressure. Ideally, they should be located at right angles to the sheets, but since the outer sheet (wrapper sheet) is radial and the top of the firebox (crown sheet) is relatively flat by comparison, such a relationship to both sheets is impossible. The actual location of the stays is a compromise. Since stay breakage is hidden, the stays have longitudinal holes, called tell-tales, drilled in them which will blow water and steam, revealing if they are broken. A boiler with more than 5 broken stays (no two next to each other) must be taken out of service and the stays replaced. The fusible plugs, usually located in the highest part of the crown sheet, have a soft metal alloy core which melts out if the water level in the boiler gets too low. Steam and water blowing into the firebox both alerts the locomotive crew to the low water condition and helps put out the fire. Not all locomotives are equipped with fusible plugs. Also, fusible plugs should be replaced at regular intervals, about every three months for a locomotive in regular service, because the soft metal alloy core will slowly melt out over time even if the boiler water is carried at proper levels. The "mudholes," or washout plugs, allow access to the interior of the boiler for washing and scraping away boiler mud and scale.

The sheets on the left and right are called "side sheets" while the sheet in the front of the firebox is the flue sheet. The "front flue sheet" is in the front of the boiler and at the rear of the smokebox. The "rear sheet" is at the back of the firebox and has the door opening in it. The crown sheet is the top of the firebox. The crown sheet must be covered by water at all times. If the water level drops below the crown sheet, it will become overheated and start to melt and deform, usually sagging between the crown stays. If the condition continues, the crown sheet will eventually be forced off the crown stays by the pressure in the boiler, resulting in a boiler explosion. This condition, usually caused by human error or inattention, is the single greatest cause of a locomotive boiler explosion.

Belpaire firebox

Normally the top of the boiler (wrapper sheet) over the firebox is radial to match the contour of the boiler; however, due to the problem of placing stays at right angles to both the wrapper sheet and the crown sheet (see above) the Belpaire firebox was developed. In the Belpaire design, the wrapper sheet is roughly parallel with the firebox sheets to allow better placement of the stays. This arrangement gives the firebox end of the boiler a more square shape and is usually made as large as possible within the loading gauge, to offer the greatest heating surface where the fire is hottest. The most notable user of the Belpaire firebox in the United States was the Pennsylvania Railroad. Other railroads, such as the Great Northern and Illinois Central, had locomotives with Belpaire fireboxes. Illinois Central 4-6-0 #382, Casey Jones' engine, had a Belpaire firebox.

Wootten firebox

The Wootten firebox was very tall and wide to allow combustion of anthracite coal waste. Its size necessitated unusual placement of the crew, examples being camelback locomotives.

Combustion chamber

Some fireboxes were equipped with a so-called combustion chamber which placed additional space between the fire and the rear flue sheet. This allowed more complete combustion and increased firebox surface area for greater heat transfer.

Fireman's duties

The fireman's role on a steam locomotive is to ensure the driver has an adequate supply of steam at his disposal at all times. This is achieved by maintaining a supply of fuel to the fire, and by maintaining the boiler water level so that it covers the firebox crown sheet at all times – otherwise, the latter will overheat and weaken, and a boiler explosion may result. At the terminal after the day's work is done, the fireman will fill the boiler with water and either bank or dump the fire (i.e. extinguish the fire), according to company policy, and chock the driver wheels to prevent the locomotive from moving while it is unattended.[3]

Road locomotive firebox

Road locomotives, such as traction engines, usually had fireboxes similar to those on railway locomotives but there were exceptions, e.g. the Sentinel steam waggon which had a vertical water tube boiler.

Stationary boiler firebox

There were, and are, many different designs of firebox for stationary boilers. In flue-type boilers (e.g. the Lancashire boiler) the flues themselves form the firebox. In water-tube boilers, the firebox is usually a firebrick-lined compartment below the water tubes.

Marine boiler firebox

In marine boilers there are also various types of firebox. The main distinction is, again, between fire-tube types (e.g. the Scotch boiler, with internal firebox) and water-tube types (e.g. the Yarrow boiler, with external firebox).

See also

Wikimedia Commons has media related to Firebox.

References

  1. John Daniel (April 16, 2013). "Basic features of a steam locomotive". Part 4 - Firebox layout. The Great Western Archive. Retrieved 10 September 2015.
  2. Steam Trains In Knoxville, Tennessee (2015). "Parts of the Steam Locomotive". How a Steam Engine Works. Three Rivers Rambler. Retrieved 10 September 2015.
  3. Smithsonian Institution, America on the Move.
This article is issued from Wikipedia - version of the 7/12/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.